The Message Events dialog contains all event sensors that can trigger a camera action based on incoming messages.
In order to filter events, the camera provides an Event Logic: This dialog allows linking events to create logic events only if the linked events occur in a certain sequence and within the specified time frame. Another possibility to filter events is the Event Counter: It creates an event only if a certain number of events occurs within the specified time frame.
Option |
Description |
---|---|
Event Dead Time |
The event dead time defines a period of time (0..3600 s) after an event, during which no new events from the same profile are recognized. By defining an event dead time you can avoid, for example, that a complex action (person walks through the active image area) triggers multiple events. |
Event Sensor Type |
Description |
||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Network Message |
The camera can trigger an event when it receives an IP notification via TCP/IP:
NoteThis feature is not available for Web and Basic models. |
||||||||||||||||||
MxMessageSystem |
The camera can trigger events when it receives a message via the MxMessageSystem from the MxBus or the network. Set the MxMessageSystem Name that is used to trigger the event. Note that you can define several message events for the same MxMessageSystem name. A valid
MxMessageSystem-Name must start with a letter, it must not contain spaces, tabs or the characters " |
||||||||||||||||||
Serial COM In |
The camera can trigger an event when it receives a message via the serial interface (RS232).
NoteIf you perform a binary comparison, you need to enter special characters as hex notations of the ASCII code. If you have selected a timestamp when setting up the serial interface, this timestamp is part of the message and will also be analyzed. If you want to filter according to the actual contents of the message, you can use the following regular expressions:
Remember to replace Example 1. Filtering According to Any Part of The Message
|
Cliquez sur le bouton Définirpour activer les paramètres et les sauvegarder jusqu'au prochain démarrage de la caméra.
Cliquez sur le bouton Config. usine pour réinitialiser tous les paramètres de cette boîte de dialogue selon la configuration initiale (ce bouton n'est peut-être pas disponible pour toutes les boîtes de dialogue).
Cliquez sur le bouton Restaurer pour annuler les dernières modifications qui n'ont pas été enregistrées définitivement dans la caméra.
Cliquer sur le bouton Fermer pour fermer la boîte de dialogue. Lors de la fermeture de la boîte de dialogue, le système vérifie si les paramètres ont été modifiés. Si tel est le cas, le programme vous demande si vous souhaitez enregistrer ou non de façon permanente la configuration globale.