Table des matières  Aide en ligne MOBOTIX

Thermal Radiometry

The thermal radiometry can trigger events based on the temperature measured within the specified image areas. Note that you can define different measurement areas for every event profile.

To do so, you can create different temperature events, which react to different areas and trigger values.

Important Notes:

Edit Measurement Area

The measurement area can be defined as a rectangle or as a polygon.

Rectangle syntax:

image sensor, horizontal position, vertical position, width, height
Example 1. Rectangle Syntax
0,270,190,100,100

Polygon syntax:

image sensor, poly=<hor. coordinate>x<vert. coordinate>{/<hor. coordinate>x<vert. coordinate>}
Example 2. Polygon Syntax
0,poly=270x190/270x289/369x289/369x190

Notes

  • The measurement area refers to the entire image sensor.

  • If the camera image has been mirrored or rotated, the coordinate system of the windows changes accordingly.

Parameter

Description

Image sensor

Selects the image sensor (camera image) to use for this area definition:

  • 0: Right camera image on dual cameras, default setting on mono cameras.

  • 1: Left camera image on dual cameras.

Horizontal position

Number of pixels measured from the left edge of the visible image to the left border of the area (based on a MEGA image 1280x960).

Vertical position

Number of pixels measured from the bottom edge of the visible image to the bottom border of the area (based on a MEGA image 1280x960).

Width

Width of the area in pixels (based on a MEGA image 1280x960).

Height

Height of the area in pixels (based on a MEGA image 1280x960).

Horizontal Coordinate

Number of pixels measured horizontally from the left edge of the visible image to the polygon corner (based on a MEGA image 1280x960).

Vertical Coordinate

Number of pixels measured vertically from the bottom edge of the visible image to the polygon corner (based on a MEGA image 1280x960).

Note

If you would like to define a new measurement area, open the Environment Events dialog and follow the instructions of the Graphically Entering Image Areas help page.

Measurement Mode

Allows setting the basic mode for the trigger value. The following modes are available:

Trigger Mode

Use this parameter to specify when to trigger the event. The following modes are available:

Editing the Reference Area

The measurement area can be defined as a rectangle or as a polygon.

Rectangle syntax:

image sensor, horizontal position, vertical position, width, height
Example 3. Rectangle Syntax
0,270,190,100,100

Polygon syntax:

image sensor, poly=<hor. coordinate>x<vert. coordinate>{/<hor. coordinate>x<vert. coordinate>}
Example 4. Polygon Syntax
0,poly=270x190/270x289/369x289/369x190

Notes

  • The reference area refers to the entire image sensor.

  • If the camera image has been mirrored or rotated, the coordinate system of the windows changes accordingly.

Parameter

Description

Image sensor

Selects the image sensor (camera image) to use for this area definition:

  • 0: Right camera image on dual cameras, default setting on mono cameras.

  • 1: Left camera image on dual cameras.

Horizontal position

Number of pixels measured from the left edge of the visible image to the left border of the area (based on a MEGA image 1280x960).

Vertical position

Number of pixels measured from the bottom edge of the visible image to the bottom border of the area (based on a MEGA image 1280x960).

Width

Width of the area in pixels (based on a MEGA image 1280x960).

Height

Height of the area in pixels (based on a MEGA image 1280x960).

Horizontal Coordinate

Number of pixels measured horizontally from the left edge of the visible image to the polygon corner (based on a MEGA image 1280x960).

Vertical Coordinate

Number of pixels measured vertically from the bottom edge of the visible image to the polygon corner (based on a MEGA image 1280x960).

Note

If you would like to define a new reference area, open the Environment Events dialog and follow the instructions of the Graphically Entering Image Areas help page.

Temperature Unit

Show the temperatures either in degrees Centigrade (°C) or Fahrenheit (°F).

Trigger Values

Enter the temperature value that is used to trigger an event when it exceeds or when it drops below the value (depending on the setting of the Comparison parameter, see below).

Comparison

Select between triggering the event when it exceeds or when it drops below the specified trigger value.

Action Type

Define how often the event is to be triggered:

Show Measurement Area

To display the measurement area of a Thermal Radiometry event profile in the live image, select a color from the selection list. In addition, you can set the following options for the measurement area:.

The following options are available for the measurement area, the temperature value and the profile name:


Sauvegarder la configuration

Cliquez sur le bouton Définirpour activer les paramètres et les sauvegarder jusqu'au prochain démarrage de la caméra.

Cliquez sur le bouton Config. usine pour réinitialiser tous les paramètres de cette boîte de dialogue selon la configuration initiale (ce bouton n'est peut-être pas disponible pour toutes les boîtes de dialogue).

Cliquez sur le bouton Restaurer pour annuler les dernières modifications qui n'ont pas été enregistrées définitivement dans la caméra.

Cliquer sur le bouton Fermer pour fermer la boîte de dialogue. Lors de la fermeture de la boîte de dialogue, le système vérifie si les paramètres ont été modifiés. Si tel est le cas, le programme vous demande si vous souhaitez enregistrer ou non de façon permanente la configuration globale.


© 2001-2024 MOBOTIX, · http://www.mobotix.com/